Copper alloy induction heating melting furnace
1. Production Guidelines:
(1). Raw material: Copper and aluminum
(2). Heating method: electromagnetic induction heating.
(3). Production purpose: to melt the Copper or aluminum solution and adjust its composition (add a small amount of trace elements, such as Ni, Cu, Mg, etc.), and at the same time, determine whether to add a modifier to modify the copper liquid according to the modification effect.
2. Equipment type:
The equipment is equipped with crucible type electromagnetic induction heating copper melting electric furnace.
3. Number of equipment: one digital power supply and one furnace body
(1). Model 1: RLKS-2000RT electromagnetic induction heating copper melting electric furnace
(1.1)Technical parameters
Copper alloy induction heating melting furnace
1. Production Guidelines:
(1). Raw material: Copper and aluminum
(2). Heating method: electromagnetic induction heating.
(3). Production purpose: to melt the Copper or aluminum solution and adjust its composition (add a small amount of trace elements, such as Ni, Cu, Mg, etc.), and at the same time, determine whether to add a modifier to modify the copper liquid according to the modification effect.
2. Equipment type:
The equipment is equipped with crucible type electromagnetic induction heating copper melting electric furnace.
3. Number of equipment: one digital power supply and one furnace body
(1). Model 1: RLKS-2000RT electromagnetic induction heating copper melting electric furnace
(1.1)Technical parameters
No. |
Name |
Unit |
Parameter |
1 |
Rated Capacity(Copper Liquid) |
T |
2.0 |
2 |
Digital power supply rated variable frequency maximum power |
kW |
300 |
3 |
Operating Voltage |
V |
380 |
4 |
Working frequency |
Hz |
50 |
5 |
Working temperature |
ºC |
1600 |
6 |
Melting rate |
Ton/h |
1.0 |
7 |
Power consumption (Per ton of copper liquid) |
Kw/Ton |
300 |
8 |
Voltage regulating transformer capacity |
KVA |
315(Should be prepared by buyer) |
9 |
Hydraulic motor power |
KW |
2 |
10 |
Cooling water pump power |
KW |
3(Should be prepared by buyer) |
11 |
Maximum rotation angle of furnace body |
degree |
95 |
12 |
Degree of three-phase current imbalance |
% |
<0.2 |
13 |
Power factor |
|
≥0.99 |
14 |
Pressure medium |
Water-based glycol 68# |
Should be prepared by buyer |
15 |
Cooling water |
Hydraulic pressure |
0.2~0.4 |
0.2~0.4 |
|
|
Water inlet temperature |
<35 |
<35 |
|
|
Water outlet temperature |
<55 |
<55 |
|
|
Cooling tower water flow rate |
Ton/h |
40 |
16 |
Built-in crucible container size |
mm |
Inner diameter 530 × height 1200 |
17 |
Furnace body weight |
T |
About 1.5T |
Remarks: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|